- Product description
-
Product description
Lightning current arrester, type 1+2 for surge voltage protection and the safe arresting of partial lightning currents following the EN 61643-11 standard.
• Lightning current arresting capacity 12.5 kA (10/350)
• Modular connectable arrester with cut-off unit and visual status display
• Locking mechanism with vibration protection and voltage keying
• Plastic to UL 94 V-0
• With potential-free changeover contact for remote signalling
- Technical data
-
Technical data
Conductor cross-section, flexible (fine-wire), max. 2 AWG Conductor cross-section, flexible (fine-wire), max. 35 mm² Conductor cross-section, flexible (fine-wire), min. 16 AWG Conductor cross-section, flexible (fine-wire), min. 1,5 mm² Conductor cross-section, rigid (single-wire/multiwire), max. 35 mm² Conductor cross-section, rigid (single-wire/multiwire), max. 2 AWG Conductor cross-section, rigid (single-wire/multiwire), min. 1,5 mm² Conductor cross-section, rigid (single-wire/multiwire), min. 16 AWG Connection cross-section, FM terminals, max. 16 AWG Connection cross-section, FM terminals, max. 1,5 mm² Connection cross-section, FM terminals, min. 0,5 mm² Connection cross-section, FM terminals, min. 21 AWG DC network form no Dimension 60V DC FM contacts Changeover Housing material surge protection components PA UL 94 V-0 Installation type DIN rail 35 mm IT network form no Lightning surge current (10/350 μs) 12,5 kA Max. mains-side overcurrent protection 160 A gL/gG Maximum back-up fuse 160 A Maximum continuous voltage (L-N) 150 V Maximum continuous voltage DC 60 V Maximum discharge current (8/20 μs) 50 kA Maximum discharge current (8/20 μs) [L-N] 50 kA Minimum distance 1,5 mm Network form DC Nominal discharge current (8/20 µs) 30 kA Nominal voltage AC (50/60 Hz) 120 V Operating temperature, max. 80 °C Operating temperature, min. -40 °C Other network form no Pole number 1 Pole version 1 Protection level [L-N] ≤0,8 Protection rating IP20 Residual voltage [L-N] @ 1 kA 0,4 kV Residual voltage [L-N] @ 12.5 kA 0,6 kV Residual voltage [L-N] @ 5 kA 0,5 kV Response time <25 ns Short-circuit resistance for max. mains-side overcurrent protection 50 kA eff Signalling on device Visual SPD to EN 61643-11 Type 1+2 SPD to IEC 61643-1 Class I+II SPD to UL 1449 Type 4 Switching power AC 230 V; 0,5 A Switching power DC 230 V; 0,1 A / 75 V; 0,5 A TN network form no TN-C network form no TN-C-S network form no TN-S network form no Torque 4 Nm TT network form no - All types
- Downloads
-
Data sheet V50-DC-60-12,5FS / 5093447 , 0.26MB , pdfCatalogue Überspannungsschutz , 28.42MB , pdfMounting instructions Combi Controller V50 - V50-DC-60-12,5FS , 1.13MB , pdf
Singapore - English